Water purification information

Do you know what factors affect reverse osmosis desalination rate?

Views : 15127
Author : Susan
Update time : 2024-09-27 16:23:44
Do you know what factors affect reverse osmosis desalination rate?

Hello everyone, today Susan is here to answer some questions about water treatment equipment, hope it can help you.

13 Factors Affecting Reverse Osmosis Desalination Rate
Desalination rate is the percentage of the concentration of soluble impurities removed from the equipment feed water through the reverse osmosis membrane. Desalination rate = (1 - salt content of produced water / salt content of feed water) x 100%.

The desalination rate of the reverse osmosis membrane element has been determined when it is manufactured, and the high and low desalination rate depends on the density of the ultra-thin desalination layer on the surface of the reverse osmosis membrane element, and the denser the desalination layer is, the higher the desalination rate is, and the lower the amount of water produced at the same time. The desalination rate of reverse osmosis for different substances is mainly determined by the structure and molecular weight of the substances, the desalination rate of imported reverse osmosis membrane element for high valence ion and its complex monovalent ion can be more than 99%, and the desalination rate for monovalent ions, such as sodium ion, potassium ion and chlorine ion is a little bit lower, but it is also more than 98%; and the desalination rate for the organic matter with molecular weight more than 100 can also reach 98%.

Factors affecting the desalination rate of reverse osmosis are:
◆ Ion valence number             
Desalination rate is increased with the increase of ion valence, and the desalination rate of bivalent and trivalent salt is higher than that of monovalent salt.
◆ Molecule size              
The desalination rate increases with the increase of molecular diameter.
◆ Raw water temperature              
When the temperature of raw water increases, the desalination rate increases because the viscosity of water decreases.
◆ Raw water concentration              
Desalination rate decreases when raw water concentration increases.
◆Working pressure              
When the working pressure increases, the desalination rate increases, but it is not obvious.
◆ PH value              
The desalination rate decreases under acidic condition though the membrane is not easy to be clogged.
◆ Dissolved gas              
Soluble gases are easy to permeate without removing CO2, SO2, O2, Cl2, H2S, etc. in free state;
◆Hydrogen bonding tendency           
The removal rate is very low for compounds with strong hydrogen bond, such as water, phenol and ammonia, etc. (It is also realized to remove impurities and dissolved substances in water to separate them from other substances.
◆Organic substances              
Organic matter in water has a contaminating effect on the membrane, and the more organic matter there is, the more easily the performance of the membrane deteriorates.
◆ Water hardness              
The higher the hardness of water, the easier it is to block the membrane. For high hardness water, it should be softened first, and the hardness should be reduced before entering reverse osmosis.
◆ Solid particles              
Solid particles are very harmful to reverse osmosis membrane and must be pre-treated.
◆ Microorganisms            
Microorganisms and bacteria in the water are harmful to the membrane and must be pre-treated (our company adopts ultra-rate membrane for treatment, which is at the advanced level in China).
◆Oxide             
Metal oxides can not be removed by themselves when they enter reverse osmosis, and should be removed by chemical drugs regularly.

Related News
Read More >>
Do you know what is the most reasonable recovery rate setting for RO system? Do you know what is the most reasonable recovery rate setting for RO system?
Oct .28.2024
When discussing design options with peers and customers, the question of the reasonableness of the system's recovery rate setting often comes up. The essence of the problem is to set the recovery rate has exceeded the upper limit of the recovery rate of the system (limit recovery rate).
Do you know the difference between ultrapure water equipment and pure water equipment? Do you know the difference between ultrapure water equipment and pure water equipment?
Oct .28.2024
Do you know the difference between ultrapure water equipment and pure water equipment?
Here Susan will let you know what the differences between them.
Reverse osmosis ultrapure water equipment common faults (with solutions) Reverse osmosis ultrapure water equipment common faults (with solutions)
Oct .25.2024
Reverse osmosis ultrapure water equipment is a kind of equipment used to remove impurities and pollutants in water, but it is inevitable that it will encounter some problems in the course of its usual operation and use, so how should it solve these problems? The following are some common water purifier problems with corresponding solutions:
​​​​​​​Factors affecting the effectiveness of activated carbon filtration and methods of use ​​​​​​​Factors affecting the effectiveness of activated carbon filtration and methods of use
Oct .25.2024
​​​​​​​Factors affecting the effectiveness of activated carbon filtration and methods of use
The adsorption capacity of activated carbon is related to the water temperature and water quality.The adsorption principle of activated carbon。